Suunto si impegna per assicurare che questo sito web raggiunga il livello AA di conformità alle Web Content Accessibility Guideline (WCAG) 2.0 e la conformità ad altri standard di accessibilità. Se riscontri problemi con l'accesso alle informazioni di questo sito web, ti preghiamo di contattare il Servizio Clienti al numero verde +1 855 258 0900 (Stati Uniti).

Suunto Zoop Novo User Guide

Dive modes

Suunto Zoop Novo has the following dive modes:

  • Air: for diving with regular air
  • Nitrox: for diving using oxygen-enriched gas mixtures
  • Gauge: for using the dive computer as a bottom timer
  • Free: for freediving
  • Off: turns dive mode off completely; the dive computer does not automatically switch the dive mode when submerged and dive planning mode is hidden

By default, Air mode is activated when you enter dive mode. You can change which mode is activated or turn dive mode off under the general settings.

To change dive modes:

  1. While in time mode, keep DOWN pressed.
  2. Press SELECT to enter Dive Mode.
  3. Change to the desired mode with UP or DOWN and confirm with SELECT.
  4. Press MODE to exit.

Each dive mode has its own settings which you need to adjust while in the given mode.

To modify dive mode settings:

  1. While in a given dive mode, keep DOWN pressed.
  2. Press DOWN or UP to scroll through the settings.
  3. Press SELECT to enter a setting.
  4. Adjust the setting with DOWN or Up and confirm with SELECT.
  5. Press MODE to exit.
NOTE:

Some settings cannot be changed until five (5) minutes have elapsed after the dive.

Air mode

Air mode is for diving with regular air and has the following settings:

Nitrox mode

Nitrox mode is for diving with oxygen-enriched gas mixtures.

Diving with nitrox allows you to increase bottom times or reduce the risk of decompression illness. However, when the gas mix is altered or depth increased, the oxygen partial pressure is generally increased. Suunto Zoop Novo provides you with information to adjust your dive and stay within safe limits.

Nitrox mode has the following settings

In Nitrox mode, both the percentage of oxygen in your tank and the oxygen partial pressure limit must be entered into Suunto Zoop Novo.

This ensures correct nitrogen and oxygen calculations and the correct maximum operating depth (MOD), which is based on your entered values.

The default oxygen percentage (O2%) setting is 21% (air) and oxygen partial pressure (PO2) setting is 1.4 bar (20 psi).

To modify gas mix settings:

  1. While in Nitrox mode, keep DOWN pressed.
  2. Press SELECT to enter the Nitrox setting.
  3. Adjust the O2 value with DOWN or UP to match the oxygen percentage of your tank and confirm with SELECT.

nitrox setting ZoopNovo

  1. Adjust the PO2 (oxygen partial pressure) value with DOWN or UP and accept with SELECT.
  2. Adjust other settings as needed.
  3. Press MODE to exit.
NOTE:

If the oxygen content of a mix is set to 22% or above, the setting value remains until changed. It does not automatically revert back to 21%.

Gauge mode

With Gauge mode, you can use Suunto Zoop Novo as a bottom timer.

The timer in the center of the display shows dive time in minutes and seconds and activates at the start of the dive. The total running dive time, in minutes, is in the lower right corner.

The timer in the center of the display can be used as a stopwatch by pressing SELECT during the dive.

Pressing SELECT resets the main timer and adds a bookmark to the dive log. The previously-timed interval is displayed below the main timer.

gauge mode timer ZoopVyperNovo

Gauge mode has the following settings

Gauge mode is a bottom timer only and thus includes no decompression information or calculations.

Free mode

With Free mode, Suunto Zoop Novo can be used as a freediving instrument. The dive time is indicated in minutes and seconds in the center of the display.

The free dive starts at 1.2 m (4 ft) and ends when your depth is less than 0.9 m (3 ft).

Free mode has the following settings:

Depth notifications

You can define up to five independent depth notifications for freediving, for example, to alert you to start free falling or mouth filling. Each notification has a defined depth and can be turned on or off.

When you reach the notification depth, the backlight blinks and the low priority audible alarm sounds.

To define depth notifications:

  1. While in Free mode, keep DOWN pressed.
  2. Press SELECT to enter the Depth Notify settings.
  3. Scroll through the notifications with DOWN or UP and enter a notification with SELECT.
  4. Press DOWN or UP to toggle the notification On/Off and confirm with SELECT.
  5. Adjust the depth with DOWN or UP and confirm with SELECT.
  6. Scroll to the next notification to modify or press MODE to exit.

Surface countdown timer

While freediving, you can use the surface countdown timer to help you prepare yourself for you next dive. Suunto Zoop Novo starts the countdown as soon as you reach 1.2 m (4 ft).

To set the surface countdown timer:

  1. While in Free mode, keep DOWN pressed.
  2. Press UP to scroll to Surf. Time Notify.
  3. Press DOWN or UP to toggle the timer on and confirm with SELECT.
  4. Adjust the countdown duration with DOWN or UP and conform with SELECT.
  5. Press MODE to exit.

Indice