Suunto is committed to achieving Level AA conformance for this website in conformance with the Web Content Accessibility Guidelines (WCAG) 2.0 and achieving compliance with other accessibility standards. Please contact Customer Service at USA +1 855 258 0900 (toll free), if you have any issues accessing information on this website.

Suunto EON Core User Guide 3.0

How to plan a dive using the Dive planner

Before planning your first dive, go through the planner settings and configure them according to your personal preference. Access the planner and adjust settings under Main menu » Dive planner.

  1. First set the values for:

    • personal gas consumption (default value: 25 L/min / 0.90 ft3)
    • tank pressure (default value: 200 bar / 3000 psi)
    • tank size (default value: 12 liters / 80 ft3, 3000 psi)
    NOTE:

    It is important to adjust these values first to get the gas calculations right.

  2. Use the lower or upper buttons to decrease or increase the values. If you are not sure what your personal gas consumption is, we recommend using the default value of 25 L/min (0.90 ft3/min).

    NOTE:

    Estimated gas time is calculated based on tank pressure at start minus 35 bar (510 psi).

You can adjust dive depth, dive gas O2 percentage and surface time interval in View planner.

Based on these parameters, Dive planner shows no decompression dive time for your planning purposes. If tank size, tank pressure and gas consumption are filled, planner shows gas time calculation too.

Dive planner EonCore

The calculated no decompression time is based on dive depth and gas mixture. Any residual nitrogen from previous dives, as well as surface time, is taken into consideration. Gas time is dependent on the dive depth, gas mixture, personal consumption, tank size and tank pressure.

Planning the first dive in a series

  1. Edit depth and mixture in View planner.
  2. As an example, enter 18 meters, use compressed air as a gas mixture, and you will see the following:

    dive planner 1 eon

    In this example, the calculated values are:

    1. Dive number in the dive series: 1
    2. Available no decompression time: 51 minutes
    3. Remaining gas time: 41 minutes

Planning additional dives

The dive planner allows you to adjust surface time in 10-minute increments. 48:00 hours is the maximum value to be set.

In the example below, the surface time before the second dive is 1 hour 37 minutes. Adjust surface time to see how it impacts no decompression time.

Diveplanner2